New Best Practice Guides for Laboratories Now Available

August 28, 2007

The Laboratories for the 21st Century program (Labs21) has published several new best practice guides on specific technologies that contribute to energy efficiency and sustainability in laboratories. The guides were developed by the Labs21 technical team, with significant participation from industry experts. Each guide was also peer reviewed for technical accuracy. Each includes a description of the technology and provides specific best-practice strategies along with performance metrics and implementation examples. Since a full description of each guide is beyond the scope of this article, we encourage the reader to download them from the Web site for more detailed information.

Modeling Exhaust Dispersion

The standard practice for designing exhaust stacks in laboratories involves the use of prescriptive guidelines, which may oversize the system while not necessarily meeting performance requirements. The practice strategies described in the guide include ASHRAE and Environmental Protection Agency (EPA) calculation and graphical methods, plume dispersion calculations, computational fluid dynamics, and wind tunnel modeling. These methods provide a more accurate assessment of exhaust dispersion. They can be used to produce exhaust/intake designs optimized for energy consumption, taking into account stack height, volume flow rate, exit velocity, expected pollutant emission rates, and concentration levels at sensitive locations.

Water Efficiency in Laboratories

Laboratories offer significant opportunities for water savings. Some of these opportunities, such as increasing the concentration ratio for cooling tower water, rainwater harvesting, etc., are common to other commercial buildings. However, this guide focuses on strategies that are unique to laboratories, such as:

Labs21 Best Practice Guides

Right-Sizing Laboratory Equipment Loads

Peak equipment loads in laboratories are frequently overestimated because designers often use estimates based on "nameplate" rated data, or design assumptions from prior projects. These estimates result in oversized heating, ventilation, and air conditioning HVAC systems, increased initial construction costs, and increased energy use due to inefficiencies at low part-load operation. This best-practice guide presents a case study of over-sizing, and then describes best practice strategies to obtain better estimates of equipment loads and right-sized HVAC systems. Some of these strategies include:

Minimizing Reheat in Laboratories

Load variation across different laboratory spaces can significantly increase simultaneous heating and cooling, particularly for systems that use zone reheat for temperature control. This best practice guide describes the problem of simultaneous heating and cooling resulting from load variations, and presents several technological and design process strategies to minimize it:

Optimizing Laboratory Ventilation Rates

Ventilation is often the largest component of energy use in a laboratory. Various codes and standards recommend a wide range of minimum ventilation rates — from 4 to 12 air changes per hour. In many laboratories, these minimum ventilation rates are set at excessively high levels even though more air changes do not necessarily improve safety. The challenge is to determine an optimal ventilation rate that handles both the worst scenario (possible) safely and manages routine scenarios (probable) efficiently. This guide describes a detailed deliberate decision-making process to optimize ventilation rates, with techniques such as:

Labs21 will continue to develop best practice guides on various efficiency opportunities in laboratories, and welcomes input from interested stakeholders for developing these guides.

For more information, please contact Otto Van Geet of the National Renewable Energy Laboratory, 303-384-7369.