Reliability Centered Maintenance

Reliability centered maintenance (RCM) is the maintenance approach used when following a process that assesses equipment condition and determines the maintenance requirements of any physical asset in its operating context.

Basically, the RCM methodology addresses key issues not dealt with by other maintenance programs. This approach recognizes that all equipment in a facility is not of equal importance—to either the process or to facility needs and safety. Focusing on reliability of equipment means recognizing that equipment design and operations differ, and that each piece of equipment will have a different probability of undergoing failure from degradation than will another. A reliability-focused approach will mean structuring a maintenance program based upon the understanding of equipment needs and priorities, as well as limited financial and personnel resources, to plan activities such that equipment maintenance is prioritized while operations are optimized.

Simply put, RCM is a systematic approach of evaluating a facility's equipment and resources to best match the two needs. This results in a high degree of facility reliability and cost-effectiveness, and is highly reliant on predictive maintenance. However, it also recognizes that maintenance activities on equipment that is inexpensive and less important to overall facility reliability may be best left to a reactive maintenance approach, focusing both labor and financial resources on higher priority and more costly equipment. The following maintenance program breakdowns of continually top-performing facilities echo the RCM approach, which utilizes all available maintenance tactics. As is shown, all maintenance approaches are used, but the predominant strategy used is predictive.

  • <10% Reactive
  • 25% to 35% Preventative
  • 45% to 55% Predictive

Because RCM is so heavily weighted on utilization of predictive maintenance strategies, its program advantages and disadvantages mirror those of predictive maintenance. In addition to these advantages, RCM will allow a facility to more closely match its resources to operational needs and at the same time improve both reliability and also reduce associated maintenance costs.

Advantages and Disadvantages

Advantages

  • Can be the most efficient maintenance program
  • Lowers costs by eliminating unnecessary equipment maintenance or system overhauls
  • Minimizes the frequency of overhauls
  • Reduces probability of sudden equipment failures
  • Focuses maintenance activities on critical system components
  • Increases component reliability
  • Incorporates root cause analysis

Disadvantages

  • Can have significant startup costs associated with staff training and equipment needs
  • Savings potential is not readily seen by management