How to Buy Products with Low Standby Power

ENERGY STAR Qualified Products

Information about low standby power in this section includes the following:

Efficiency Recommendation
Cost-Effectiveness Example
Federal Supply Sources
 Standby vs. Sleep Modes
Identifying Products with Low Standby Power
For More Information

Also provided is a portable document format version of How to Buy Products with Low Standby Power (PDF 234 KB, 2 pp). Download Adobe Reader.

Efficiency Recommendation
Product Type Recommended Standbyb Levels Best Available Standby Level
Office Equipment
Desktop Computera 2 watts or less 1 watt or less
Integrated Computera,c 3 watts or less 3 watts or less
Laptop Computer 1 watt or less 1 watt or less
Workstationa,d 2 watts or less 1 watt or less
Computer Monitor 1 watt or less 1 watt or less
Printera 1 watt or less 1 watt or less
Copier 1 watt or less 1 watt or less
Scanner 1 watt or less 1 watt or less
Fax/Printer 2 watts or less 1 watt or less
Multifunction Devicesa,e 1 watt or less 1 watt or less
Docking Station 2 watts or less 1 watt or less
Audio/Video Products
TV 1 watt or less 1 watt or less
VCR 2 watts or less 1 watt or less
TV/VCR/DVD Combo 3 watts or less 1 watt or less
DVD Players 1 watt or less 1 watt or less
Consumer Audio 1 watt or less 1 watt or less
Major Appliances
Microwave Oven 2 watts or less 2 watts or less

a If this product is connected to a local area network and operated continuously, then buyers should select products with the lowest possible sleep power level.
b Standby power refers to the electricity used by electrical products when they are switched off or not performing their primary purpose.
c An "integrated computer" is a product that combines the processor and display monitor in one case and draws power through a single cord.
d A "workstation" is a high-performance desktop computer that can be equipped with multiple processors and is generally dedicated to computationally intensive tasks.
e A "multifunction device" is a product that perfroms two or more of the following: copying, faxing, scanning, or printing. Fax machines that do convenience copying (single sheet) are not considered multifunction devices for purpose of determining standby power.

Back to Top

Cost-Effectiveness Rule of Thumb for Products with Low Standby Power
1 watt saved in standby power = $1.25 savings in lifetime energy costsa

a Lifetime energy cost is the sum of the discounted present values of future annual energy costs. Future electricity price trends and a discount rate of 3.0% are based on federal guidelines (effective from April, 2003 to March, 2004).

For example, an agency buying 200 low-standby monitors (at 1 watt instead of 3 watts) will save $500 over the life of the monitors. This assumes an average of 6000 hours per year in standby ("off") mode and a typical product life of 4 years. Products with low standby power typically do not cost more to purchase.

Back to Top

Federal Supply Sources

Standby Power Data Center

FEMP maintains an on-line database of products that meet this recommendation. For a current list of models visit the Standby Power Data Center.

FEMP is currently working with the Defense Logistics Agency (DLA) and the General Services Administration (GSA) to help federal buyers identify products with low standby power in catalogs and supply schedules. When buying or specifying any of the products listed in the table above, make sure the product qualifies for the ENERGY STAR® label and also meets the recommended low standby power level. Some, but not all, ENERGY STAR® labeled products have low standby power levels as defined by Executive Order 13221 (PDF 84 KB, 3 pp). ENERGY STAR® is currently updating their on-line database to include data on low standby power products based on this efficiency recommendation.

Back to Top

Standby vs. Sleep Modes

For some products, low-power standby mode is different from (lower than) the "sleep" mode required by ENERGY STAR®. All ENERGY STAR® labeled computers, monitors, copiers, printers, and fax machines will switch into a low-power "sleep" mode after a specified period of non-use. When needed, these devices return automatically to the active mode (displaying an image, copying, receiving a fax, etc.). Standby mode differs because the user—not the machine itself—generally switches off the device and must manually turn it back on.

Back to Top

Identifying Products with Low Standby Power

The only way to be certain if a product consumes standby power is to measure it with a watt-meter. However, here are a few clues to help identify products with standby power:

  • An external power supply (i.e., cell phone chargers, inkjet printers).
  • A remote control (i.e., TVs, VCRs, ceiling fans, audio equipment).
  • A continuous digital display (i.e., clothes washers, microwaves, VCRs).
  • A rechargeable battery (i.e., cordless telephones, battery charger). These products continue to use standby power even after the battery is fully charged.

Some products without these features also consume standby power. Many switches labeled "off" do not completely shut off power. For example, certain halogen desk lamps with low-voltage power supplies consume power even when the light is off. The only devices that do not consume standby power are those with a switch that physically breaks the circuit.

Back to Top

For More Information

  • DOE's Federal Energy Management Program (FEMP) Help Desk and web site have up-to-date information on energy-efficient federal procurement, including the latest versions of purchasing recommendations for other products. FEMP has an online database of products that meet this recommendation for low standby power.
    Phone: (877) 337-3463
  • Environmental Protection Agency (EPA) has ENERGY STAR® product listings and purchasing specifications for products with low standby power.
    Phone: (888) STAR-YES (782-7937)
  • Lawrence Berkeley National Laboratory provided supporting analysis for this recommendation on products with low standby power.
    Phone: (202) 646-7950

Back to Top