FEMP Designated Product: Residential Freezers

ENERGY STAR Qualified Products

Legal Authorities

Federal agencies are required by the Energy Policy Act of 2005 (P.L. 109-58) and Federal Acquisition Regulations (FAR) Subpart 23.2 to specify and buy ENERGY STAR®-qualified products or, in categories with no ENERGY STAR label, FEMP-designated products which are among the highest 25 percent of equivalent products for energy efficiency.

Information about energy-efficient residential freezers in this section includes the following:

Performance Requirements for Federal Purchases
Buying Energy-Efficient Residential Freezers
Size and Type Selection
Cost-Effectiveness Example
Cost-Effectiveness Assumptions
Using the Cost-Effectiveness Table
What if my Freezer Type or Electricity Price is Different?
For More Information

Also provided is a portable document format version of Purchasing Specifications for Residential Freezers (PDF 281 KB, 2 pp). Download Adobe Reader.

Performance Requirement for Federal Purchases
Freezer Type–Defrost Total Volume Annual Energy Usea
Chest–Manual <6.4 cu. ft. 230 kWh/year or less
Chest–Manual 6.5 to 8.4 cu. ft. 260 kWh/year or less
Chest–Manual 8.5 to 10.4 cu. ft. 290 kWh/year or less
Chest–Manual 10.5 to 12.4 cu. ft. 320 kWh/year or less
Chest–Manual 12.5 to 14.4 cu. ft. 350 kWh/year or less
Chest–Manual 14.5 to 16.4 cu. ft. 380 kWh/year or less
Chest–Manual 16.5 to 18.4 cu. ft. 410 kWh/year or less
Chest–Manual 18.5 to 20.4 cu. ft. 440 kWh/year or less
Chest–Manual >20.5 cu. ft. 470 kWh/year or less
Upright–Manual <6.4 cu. ft. 305 kWh/year or less
Upright–Manual 6.5 to 8.4 cu. ft. 330 kWh/year or less
Upright–Manual 8.5 to 10 cu. ft. 355 kWh/year or less
Upright–Manual 10.5 to 12.4 cu. ft. 380 kWh/year or less
Upright–Manual 12.5 to 14.4 cu. ft. 405 kWh/year or less
Upright–Manual 14.5 to 16.4 cu. ft. 430 kWh/year or less
Upright–Manual 16.5 to 18.4 cu. ft. 455 kWh/year or less
Upright–Manual 18.5 to 20.4 cu. ft. 480 kWh/year or less
Upright–Manual >20.5 cu. ft. 505 kWh/year or less
Upright–Automatic <12.4 cu. ft. 530 kWh/year or less
Upright–Automatic 12.5 to 14.4 cu. ft. 565 kWh/year or less
Upright–Automatic 14.5 to 16.4 cu. ft. 600 kWh/year or less
Upright–Automatic 16.5 to 18.4 cu. ft. 635 kWh/year or less
Upright–Automatic 18.5 to 20.4 cu. ft. 670 kWh/year or less
Upright–Automatic >20.5 cu. ft. 705 kWh/year or less

a Annual energy use is based on DOE test procedure (10 CFR 430, Sub-Part B, Appendix E).

Back to Top

Buying Energy-Efficient Residential Freezers

When buying residential freezers directly from commercial sources, select products that are ENERGY STAR-qualified (see For More Information), all of which meet the annual energy use (kWh/year) in the Performance Requirement table. For products that don't display the ENERGY STAR, check the annual energy use listed on the yellow EnergyGuide label for models that meet this Specification.

Performance requirements apply to all forms of procurements, including: guide and project specifications; construction, renovation, repair, maintenance and energy service contracts, lease agreements and solicitations for offers. Energy performance requirements should be included in all evaluations of solicitation responses. Model language to assist agencies with incorporating these performance requirements into their procurement documents is available here.

The federal supply source for residential freezers is the General Services Administration (GSA), which sells them through its Multiple Awards Schedules program and on-line shopping network, GSA Advantage! Note that not all residential freezers sold by GSA are ENERGY STAR-qualified and some that do qualify may not be indicated as ENERGY STAR. When buying freezers through this source, check the models you are considering against the list of qualified products on the ENERGY STAR web site to assure they meet this Specification.

Back to Top

Size and Type Selection

Select a freezer size and type that is appropriate for the amount of food or material stored. An oversized freezer will increase purchase cost, require more space and also waste energy due to unused capacity. Chest freezers are more efficient than upright models because they typically have more insulation and cold air does not sink out of them when they are opened. Freezers with automatic defrost use more energy than manual defrost products and can also dehydrate food causing "freezer burn."

Back to Top

Cost-Effectiveness Example
Performance Base Modela Required Best Availableb
Annual Electricity Use 687 kWh 635 kWh 616 kWh
Annual Energy Cost $42 $38 $37
Lifetime Energy Costc $545 $500 $485
Lifetime Energy Cost Savings $45 $60

a The efficiency of the Base Model is the minimum allowed by current US DOE appliance standards (10 CFR 430, Sub-part B, Appendix A1).
b More efficient products may have been introduced to the market since this specification was published. Information on the Best Available model was obtained from the ENERGY STAR freezer products list (see For More Information).
c Lifetime Energy Cost is the sum of the discounted value of the annual energy costs based on average usage and an assumed freezer life of 19 years. Future energy price trends and a discount rate of 3.0% are based on federal guidelines (effective from April, 2005 to March, 2006).

Back to Top

Cost-Effectiveness Assumptions

In the example above, annual energy use was calculated with the standard DOE test procedure on a 16.5 to 18.4 cubic foot, upright freezer with automatic defrost. The assumed electricity price is 6¢ per kWh, the average at federal facilities in the US.

Back to Top

Using the Cost-Effectiveness Table

In the example above, the Required freezer is cost-effective if its purchase price is no more than $45 above the price of the Base Model. The Best Available model is cost-effective if its price is no more than $60 above that of the Base Model.

Back to Top

What if my Freezer Type or Electricity Price is different?

ENERGY STAR has an EXCEL-based cost calculator for freezers on it's Web site, click on Savings Calculator–Consumer Residential Freezers. Select the freezer type and input the rate for electricity at the top of the page. The output section will automatically display results that better reflect your conditions.

Back to Top

For More Information

Back to Top