| Vary equipment size, energy cost, hours of operation, and /or efficiency level. |
| INPUT SECTION |
| Input the following data (if any parameter is missing, calculator will set to default value). |
Defaults |
| Type of Water Heater |
|
Electric |
| Average Daily Usage (gallons per day)* |
gallons |
64* |
| Energy Factor†|
|
0.92 (electric)
0.61 (gas) |
| Energy Cost |
$ / |
$0.06 per kWh
$.60 per therm |
| Quantity of Water Heaters to be Purchased |
unit(s) |
1 unit |
* See assumptions for various daily water use totals.
†The comparison assumes a storage tank water heater as the input type. To allow demand water heaters as the comparison type, users can specify an input EF of up to 0.85; however, 0.66 is currently the best available EF for storage water heaters.
|
| OUTPUT SECTION |
| Performance per Water Heater |
Your
Choice |
Base
Model |
FEMP
Recommended
Level |
Best
Available |
| New Energy Factor |
|
|
|
|
| Annual Energy Use |
|
|
|
|
| Annual Energy Costs |
$<>
|
$ |
$ |
$ |
| Lifetime Energy Costs |
$ |
$ |
$ |
$ |
| Lifetime Energy Cost Savings |
$ |
$ |
$ |
$ |
| Lifetime Energy Cost Savings for Water Heater(s) |
$ |
$ |
$ |
$ |
|
Your selection of a water heater using gallon(s) per day will have a $ energy cost savings per water heater over an estimated 13 year life expectancy compared to the model.
|
Assumptions
- "Base model" has an efficiency that just meets the national minimum standard for gas and electric water heaters.
- Lifetime energy cost is the sum of the discounted value of the annual energy costs based on assumed water heater life of 13 years.
- Future electricity price trends and a discount rate of 3.2% are based on Federal guidelines.
- $0.06 per kWh for electricity is the Federal average price in the U.S.
- $0.60 per therm for gas is the Federal average price in the U.S.
- Hot Water usage estimates:
- Average shower (10 minutes)—20 gallons
- Average clothes washer (one load)—10 gallons
- Average dish washer (one load)—6 gallons
- Average faucet flow—2 gallons/minute
- Total average daily usage is 64 gallons per day
|
Disclaimer
This cost calculator is a screening tool that estimates a product's lifetime energy cost savings at various efficiency levels. Maintenance and installation costs do not vary significantly among the same product having different efficiencies; so, these costs are not included in this calculator tool. For a detailed life-cycle cost analysis, FEMP has developed a tool called Building Life-Cycle Cost (BLCC). This downloadable tool allows the user to vary interest rates, installation costs, maintenance costs, salvage values, and life expectancy for a product or an entire energy project. |